Features:
- Universal AC input/ Full range
- Wide Operating Ambient Temperature
(-20°C~60°C)
- High Efficiency and High Reliability
- Ultra-miniature size, low profile
- Output Protections: OLP/OVP/SCP
- All using 105°C long life electrolytic
capacitors.
- 100% full load burn-in test
|
|
| |
 |
| Part Number |
QPS-20-3.3 |
QPS-20-5 |
QPS-20-12 |
QPS-20-15 |
QPS-20-24 |
QPS-20-48 |
| Output Charateristics |
| DC Output |
3.3V |
5V |
12V |
15V |
24V |
48V |
| Rated Current |
4A |
4A |
1.67A |
1.34A |
0.84A |
0.42A |
| Current Range |
0~4A |
0~4A |
0~1.67A |
0~1.34A |
0~0.84A |
0~0.42A |
| Ripple and Noise |
0~60°C |
<50mV |
<50mV |
<50mV |
<50mV |
<50mV |
<100mV |
| -20~0°C |
<75mV |
<75mV |
<75mV |
<75mV |
<75mV |
<100mV |
| Voltage Adj. Range |
3.1~3.6V |
4.4~5.6V |
11.1V~13.1V |
13.7V~16.1V |
22.0V~25.4V |
45.6V~50.4V |
| Voltage Accuracy |
±2% |
±2% |
±2% |
±2% |
±2% |
±2% |
| Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| Load Regulation |
±2% |
±2% |
±2% |
±2% |
±2% |
±2% |
| Set-up Time |
<2.0s (115VAC input, full load); <1.0s (230VAC input, full load) |
| Hold-up Time |
>10ms (115VAC input, full load); >20ms (230VAC input, full load) |
| Temperature Coefficient |
±0.03% / °C |
| Overshoot and Undershoot |
<5.0% |
| Input Characteristics |
| Voltage Range |
90VAC~264VAC, 127-370VDC |
| Frequency Range |
47Hz-63Hz |
| Efficiency (Typical) |
115VAC Input |
69% |
76% |
79% |
80% |
80% |
80% |
| 230VAC Input |
68% |
75% |
78% |
79% |
79% |
79% |
| AC Current (max) |
<0.5A |
| Inrush Current (Typical) |
<20A@115VAC Cold start; <40A@230VAC Cold Start |
| Leakage Current |
Input-Output: <0.35mA Input-PG: <0.75mA |
| Protection |
| Over Load (OLP) |
105%~150% of rated output power, hiccup mode, auto recovery |
| Over Voltage (OVP) |
110%~140% of rated output voltage, constant voltage |
| Short Circuit (SCP) |
Long-term mode, auto recovery |
| Environmental Characteristics |
| Operating Amb. Temp and Hum. |
-20°C~60°C, 20%~90% RH Non-Condensing |
| Storage Temp. and Hum. |
-40°C~85°C: 10%-95% RH Non-Condensing |
| Safety Standards |
UL60950-1; EN60950-1: 2006 |
| Withstand Voltage |
Primary-Secondary: 3.0KVAC; <=10mA. Primary-PG: 1.5KVAC;<=10mA. Secondary-PG: 0.5KVDC;<=10mA |
| Isolation Resistance |
>= 100M ohms |
| EMI Conduction and Radiation |
Compliance to EN55022(CISPR22) Class B |
| Harmonic Current |
Compliance to EN61000-3-2, 17625.1-2003 |
| EMS Immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light industry level, criteria A |
| General Charaterisitcs |
| MTBF (MIL-HDBK-217F) |
More than 200,000 Hrs (25°C, Full load) |
| Dimensions (LxWxH) |
89 x 51 x 20 mm |
| Packing |
60 PCS/CTN. G.W: 7.6kgs |
| Cooling Method |
Cooling by free air convection |