Weco Series 401-LF |
Type 401-LF12 mm spacing 1 to 12 poles |
|
Technical Data
Center to
Center Spacing: 12 mm / .472 in.
Nominal Cross Section:
4.8 versions: 2.5 mm2 / 3874 mils2
6.3 versions: 6 mm2 / 9299 mils2
Breakdown Voltage: 4000 V.
Approval Information
UL File No.
E69841
CSA File No. LR24322
Type 401-LF (4.8 versions)
Rating | Current (A) | Voltage (V) | AWG |
---|---|---|---|
UL | 15 | 250 | 10/14 |
CSA | 15 | 300 | 16 max. |
Type 401-LF (6.3 versions)
Rating | Current (A) | Voltage (V) | AWG |
---|---|---|---|
UL | 15 | 250 | 10/14 |
CSA | 25 | 300 | 16 max. |
Material
Molding:
( 401-LFPVC) Transparent plasticised PVC
Temperature Limits (minimum values):
Short time: 80°C / 176°F
Continuous: 70°C / 158°F
Comparative Tracking Index: CTI > 400
(type 401-LFPA) Polyamide, self extinguishing to UL 94, V-2, natural
Temperature Limits:
Short time: 140°C / 284°F
Continuous: 80°C / 176°F
Low limit: -40°C / -40°F
Comparative Tracking Index: CTI > 600
Oxygen Index Rating: 25%
Tabs: tin plated brass
Options
Mark in Order Box | Description |
---|---|
CN: | Consecutive Numbering (hot stamped black numbers) |
SM: | Special Marking (please provide sketch) |
G05: | Gold Plating (5 micro inches) |
G30: | Gold Plating (30 micro inches) |
S30: | Silver Plating (30 micro inches) |
Note: If more than one option is required,
please separate each option with a dash (-)
![]() |
Ordering Information |