Weco Series 401 |
Type 40112 mm spacing 1 to 12 poles |
|
Technical Data
Center to
Center Spacing: 12 mm / .472 in.
Nominal Cross Section:
YBH versions: 1 mm2 / 1550 mils2
4.8 versions: 2.5 mm2 / 3874 mils2
6.3 versions: 6 mm2 / 9299 mils2
Breakdown Voltage: 4000 V.
Approval Information
UL File No.
E69841
CSA File No. LR24322
Type 401 (4.8 version)
Rating | Current (A) | Voltage (V) | AWG |
---|---|---|---|
UL | 25 | 250 | 10 max. |
CSA | 15 | 300 | 10 max. |
Type 401 (6.3 and YBH versions)
Rating | Current (A) | Voltage (V) | AWG |
---|---|---|---|
UL | 25 | 250 | 10 max. |
CSA | 25 | 300 | 12 max. |
Material
Molding:
(types 401) Transparent plasticised PVC
Temperature Limits (minimum values):
Short time: 80°C / 176°F
Continuous: 70°C / 158°F
Comparative Tracking Index: CTI > 400
(type 401-PA) Polyamide, self extinguishing to UL 94, V-2, natural
Temperature Limits:
Short time: 140°C / 284°F
Continuous: 80°C / 176°F
Low limit: -40°C / -40°F
Comparative Tracking Index: CTI > 600
Oxygen Index Rating: 25%
Tabs: tin plated brass
Options
Mark in Order Box | Description |
---|---|
CN: | Consecutive Numbering (hot stamped black numbers) |
SM: | Special Marking (please provide sketch) |
G05: | Gold Plating (5 micro inches) |
G30: | Gold Plating (30 micro inches) |
S30: | Silver Plating (30 micro inches) |
Note: If more than one option is required,
please separate each option with a dash (-)
![]() |
Ordering Information |