connex-electronics.com Weidmuller
Weidmuller Products Page

Analog Signal Conditioners
Back to Weidmuller Main Selection Page
Terminal Blocks
DIN Rail Blocks
PCB Blocks
PCB Connectors
PCB Headers
PCB Plugs
Heavy Duty Connectors
Contacts
Inserts
Housings
Electronics
Analog Signal Conditioners
DC/DC Converters
Optocouplers
Overvoltage Protection
Power Supplies
Relays
Interface Modules
DIP Cable
Discrete Cable
D-Sub Cable
Elco Cable
RJ Cable
SAI Cable
Tcon Cable
PLC-Field Connection
PLC-Front Panel Connection
Enclosures
Increased Safety
Standard Industrial
Accessories
DIN Rail
Ferrules
Jumpers
Marking System
Crimpers
Cutters - Strippers
  Input Signal Type - Input Signal Range
AD Converter - +/- 10 VDC
AD Converter - 0...10 V
AD Converter - 0...20 mA
AD Converter - 4...20 mA
Current - 0...1 mA
Current - 0...5 mA
Current - ±10 mA
Current - ±20 mA
Current - 0...20 mA
Current - 4...20 mA
Current - 0...20 mA (max. 15 V)
Current - 0...20 mA (4...20 mA)
Current Monitoring - 1/5/10 A - AC
Current Monitoring - 1/5/10 Aac
Current Monitoring - 0.1…2 Amps
Current Monitoring - 0…5/10 Aac
Current Monitoring - 20/40/60 Aac
Current Monitoring - 0…1/5/10 Aac
Current Monitoring - 0…20/25/30 Aac
Current Monitoring - 0…20/40/60 Aac
DA Converter - 8-bit
DA Converter - 12-bit
DC alarm - 0…10 V, 0…20 mA, 4...20 mA
DC Current - 0...20 mA
DC Current - 4...20 mA
DC Current - 0 to 20 mA or 4 to 20 mA
DC Voltage - 0...10 V
DC Voltage - -10…10 V
Frequency - 1...2 kHz
Frequency - 1...10 kHz
Frequency - 1...20 kHz
Frequency - 1...25 kHz
Frequency - 1...200 Hz
Frequency - 0…16 kHz
Frequency - 0…100 kHz
Logic - 0…24VDC
Namur Switch Amplifier - Namur
Potentiometer - 100 ohms...1 mohm
Pro Bridge Input - 0…500 mV, up to +/- 500 mV
Rotational Motion and r.p.m. monitoring - P./N. switching 24 VDC
Rotational Motion and r.p.m. monitoring - 10…7800 Hz
RTD - PT100/2 Wire
RTD - PT100/4 Wire
RTD - PT100/0/4 wire
RTD - PT100/2-/3-/4-wire/Ni100
RTD - 10 Ohm Copper, a=0.0047, 0...100°C
RTD - 10 Ohm Nickel, a=0.00672, 0...100°C
RTD - PT100, a = 0.00385, 0...100°C
Set Point Controller - 0...10 V
Set Point Controller - 0...20 mA
Setpoint Device - 0…24 V
Thermocouple - Thermocouples K, J, T, E, N, R, S, B
Thermocouple Type E - 0°C...+1000°C
Thermocouple Type J - 0°...+500°C
Thermocouple Type J - -100°C...+300°C
Thermocouple Type J - -200°C...+760°C
Thermocouple Type K - -200°C...+30°C
Thermocouple Type K - -200°C...+100°C
Thermocouple Type K - -200°C...+1200°C
Thermocouple Type N - -100°C...+1300°C
Thermocouple Type T - 0°...+200°C
Thermocouple Type T - -100°C...+400°C
Thermocouple Types J, K, T, E, N, R, S, B Configurable - -200°C...+1820°C (Depending on type)
Voltage - 0...5 V
Voltage - ±10 mV
Voltage - ±10 V
Voltage - 0...10 V
Voltage - 0...10 VDC
Voltage - 0...50 mV
Voltage - ±300 mV
Voltage monitoring - 0…450 VAC
Voltage or Current - Varible Voltage and Current
Voltage or Current - 0…10 V, 0…20 mA, 4...20 mA
Voltage or Current - 0…5 V, 0…10 V, 0…20 mA, 4...20 mA
PT100/3 - PT100/3-wire, -200°C...+800°C
PT 100 RTD 2- or 3-wire - PT100, a = 0.00385, 0...100°C
PT 100 RTD 2- or 3-wire - PT100, a = 0.00392, 0...100°C
PT 100 (according to IEC 751) - 0°C...+100°C
PT 100 (according to IEC 751) - 0°C...+120°C
PT 100 (according to IEC 751) - 0°C...+150°C
PT 100 (according to IEC 751) - 0°C...200°C, 3-wire system
PT 100 (according to IEC 751) - 0°C...300°C, 3-wire system
PT 100 (according to IEC 751) - -40°C...+100°C
PT 100 (according to IEC 751) - 50°C...150°C, 3-wire system