connex-electronics.com Moeller Electric
Moeller Miniature Circuit Breakers

  
Moeller Miniature
Circuit Breakers
FAZ-Series
Branch Circuit Breakers (UL489)
General Information
Breakers - Trip Characteristic C (Use with Inductive Loads)
Breakers - Trip Characteristic D (Use with Highly Inductive Loads)
Accessories
Bus Bar System
Incoming Supply Terminals
Technical Data
Dimensions
FAZ-Series Supplementary Circuit Breakers (UL1077)
General Information
Breakers - Trip Characteristic B (Use with Resisitive or Slightly Inductive Loads
Breakers - Trip Characteristic C (Use with Inductive Loads)
Breakers - Trip Characteristic D (Use with Highly Inductive Loads)
Accessories
Bus Bar System
Incoming Supply Terminals
Protective Accessories
Technical Data
Dimensions
Application Notes
Applying Branch Circuit Breakers and Supplementary Protectors in North America (.pdf)
 
FAZ Series - Supplementary Circuit Breakers (UL-1077)
Trip Characteristic D - Designed for Highly Inductive Loads
 
Type D Characteristics - For Highly Inductive Loads
 
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 10 to 20 x rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers, and power supplies.
 
In North America, these switches are UL recognized and CSA certified as Supplementary Protection devices. Per the intent of NEC (National Electrical Code), article 240, and CEC (Canadian Electrical Code), part 1 C22.1, supplementary breakers cannot be used as a substitute for the branch circuit protective device. They can be used to provide over-current protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided, or is not required.
 
  • Designed for highly inductive loads.
  • Response time of instantaneous trip: 10 –20 x In current rating
  • UL Recognized and CSA Certified as Supplementary Protectors
  • For international and domestic use (conform to IEC / EN60898)
 
Moeller Electric 1-Pole 2-Pole 3-Pole 4-Pole
Rated Current
In (A)
1 Pole 2 Pole 3 Pole 4 Pole
Part Number Part Number Part Number Part Number
6 FAZ-D6-1 FAZ-D6-2 FAZ-D6-3 FAZ-D6-4
8 FAZ-D8-1 FAZ-D8-2 FAZ-D8-3 FAZ-D8-4
10 FAZ-D10-1 FAZ-D10-2 FAZ-D10-3 FAZ-D10-4
13 FAZ-D13-1 FAZ-D13-2 FAZ-D13-3 FAZ-D13-4
16 FAZ-D16-1 FAZ-D16-2 FAZ-D16-3 FAZ-D16-4
20 FAZ-D20-1 FAZ-D20-2 FAZ-D20-3 FAZ-D20-4
25 FAZ-D25-1 FAZ-D25-2 FAZ-D25-3 FAZ-D25-4
32 FAZ-D32-1 FAZ-D32-2 FAZ-D32-3 FAZ-D32-4
40 FAZ-D40-1 FAZ-D40-2 FAZ-D40-3 FAZ-D40-4
 
Moeller Electric 3-Pole + Neutral
Rated Current
In (A)
3 Pole + Neutral
Part Number
6 FAZ-D6-3N
8 FAZ-D8-3N
10 FAZ-D10-3N
13 FAZ-D13-3N
16 FAZ-D16-3N
20 FAZ-D20-3N
25 FAZ-D25-3N
32 FAZ-D32-3N
40 FAZ-D40-3N