connex-electronics.com Hioki
Hioki
Hioki Data Logger Series
Add part number 8420-51 to your Quote. 8420-51 MEMORY HiLOGGER
Overview
All analog inputs fully isolated! Voltage/temperature loggers with PC networking support
  • 8420-51(8ch), 8421-51(16ch), 8422-51(32ch) All analog channels isolated.
  • Temperature, voltage, humidity, cumulative pulses, rotations
  • Max. 32-channel, 100ms high-speed multi-channel data collection
  • Simultaneous numerical and graphical display
  • Attachable Printer and I/O Module
  • Up to 16 HiLOGGERs can be connected and controlled via LAN.
CE RS-232C
STANDARD
LAN
STANDARD
Options (click for picture)
  Add part number 8993 to your Quote. 8993 DIGITAL I/O UNIT - 16-bit logic input, 16-channel output, mounts on the 8420-51/8421-51 main body   Add part number 8992 to your Quote. 8992 PRINTER UNIT - Prints up to 100 mm (3.94 in) wide, mounts on the 8420-51/8421-51 main body
  Add part number 9234 to your Quote. 9234 RECORDING PAPER - 18 m (59.06 ft), roll type, 10 rolls per package Add part number 9329 to your Quote. 9329 TERMINAL UNIT - With M3 Screws
220H PAPER WINDER - Paper width 70 mm (2.76 in) to 220 mm (8.66 in), using special-purpose AC adapter   Add part number 9726 to your Quote. 9726 PC CARD 128M - PCMCIA adapter and compact flash memory card set, 128 MB
  Add part number 9727 to your Quote. 9727 PC CARD 256M - PCMCIA adapter and compact flash memory card set, 256 MB   Add part number 9728 to your Quote. 9728 PC CARD 512M - PCMCIA adapter and compact flash memory card set, 512 MB
9729 PC CARD 1G - PCMCIA adapter and compact flash memory card set, 1 G   Add part number 9641 to your Quote. 9641 CONNECTION CORD - For pulse input, 1.5 m (4.92 ft) length
  Add part number 9653 to your Quote. 9653 HUMIDITY SENSOR - With 3 m (9.84 ft) cable Add part number 9721 to your Quote. 9721 RS-232C CABLE - Mini DIN 9-pin-D sub 9-pin, 1.5m (4.92ft) straight cable for modem connection
  Add part number 9612 to your Quote. 9612 RS-232C CABLE - Mini DIN 9-pin - Dsub 9-pin, 1.5 m (4.92 ft) cross cable for PC connection   Add part number 9642 to your Quote. 9642 LAN CABLE - 5 m (16.41 ft) length, straight through wiring, includes crossover adapter
  Add part number 9334 to your Quote. 9334 LOGGER COMMUNICATOR - Data collection program required for LAN connection with Windows 95/98/Me, WindowsNT4.0/2000   Add part number 9447 to your Quote. 9447 BATTERY PACK - 7.2 V, 2400 mAh
  Add part number 9648 to your Quote. 9648 CARRYING CASE - includes space for options 9652-01 FIXED STAND - For a hands-free frontal view of the HiLOGGER
  Add part number 9418-15 to your Quote. 9418-15 AC ADAPTER - (Supplied as standard with the 8420-51/8421-51/8422-51) Universal 100 to 240 V AC, 12 V DC/ 2.5 A output *   Add part number 9643 to your Quote.  9643 CHARGE STAND - Used with the Add part number 9418-15 to your Quote. 9418-15 AC ADAPTER to charge one Model Add part number 9447 to your Quote. 9447 BATTERY PACK

Note: By using the AC adapter provided with the HiLOGGER, the Add part number 9447 to your Quote. 9447 BATTERY PACK can be charged even without using the Add part number 9643 to your Quote. 9643 CHARGE STAND. If the charging stand, AC adapter, and battery pack are purchased separately, standalone battery charging is possible.
*   Add part number 9649 to your Quote. 9649 PROTECTIVE CASE - Basic water-proof structure, includes space for options

Note: Rubber grommets are provided for cables on the side of the Add part number 9649 to your Quote. 9649 CARRYING CASE to allow measurement while closed.
*   Add part number 9652 to your Quote. 9652 FIXED STAND - affixed with a band for mounting on a slanted surface or hanging on a wall

Note: The Add part number 9652 to your Quote. 9652 is manufactured after the order is placed. Please inquire separately regarding the shipping time.
WaveViewer - Display waveform data captured by the MEMORY HiLOGGERs on a PC MEMORY HiCORDER & MEMORY HiLOGGER Application Disk - Description of transfer commands used with the GP-IB, RS-232C and LAN interfaces with WaveViewer
Basic specifications
Measurement items Temperature, voltage, humidity (with optional sensor), cumulative pulses, rotations
Input channels Analog 8 channels isolated PHOTO-MOS relays
Pulse Inputs: 4 ch, Logic Inputs: 16 ch (using the 8993 DIGITAL I/O UNIT)
Thermocouple types K, E, J, T, N, W (WRe5-26), R, S, and B
Platinum measurement resistance types Pt 100, JPt 100, 3- and 4-line types
Analog voltage input 4 ranges: 100 mV, 1 V, 10 V, 100 V and 1-5 V f.s.
Recording interval 100 ms to 1 hour (5 s to 1 hour when measuringhumidity). Note: All input channels are scanned at high speed during each recording interval.
Digital Filter OFF/50Hz/60Hz (when set to 50 or 60Hz), the appropriate digital filter is automatically set according to the recording interval
Memory capacity Internal: 32 MB (16MW data points), External:up to 1G (9726/ 9727/ 9728/ 9729 PC card, 128MB to 1GB)
Real-Time save Waveforms are saved as binary data to the PC Card in real time. Stored data can be recalled by the instrument in blocks of 32 MB each.
PC interface RS-232C and 10Base-T Ethernet connectors
Interfaces
(optional, sold separately)
8992 PRINTER UNIT (Detachable type) or 8993 DIGITAL I/O UNIT (Detachable type) can be connected
Recording and display 5.7-inch STN color LCD, 112 mm (4.4 in) × 18 m (59.06 ft), thermal paper roll
Power supply (1) 9418-15 AC ADAPTER (12 V DC ±5 %), (2) 9447 BATTERY PACK (NiMH, when used with AC adapter, the adapter has priority), (3) 12V car battery (using connection cable – please inquire)
Dimensions, mass 234 mm(9.21 in)W × 170 mm(6.69 in)H × 52 mm(2.05 in)D, 1.4 kg (49.39 oz) (instrument only, without battery)
310 mm(12.20 in)W × 170 mm(6.69 in)H × 52 mm(2.05 in)D, 1.7 kg (59.98 oz) (with printer, without battery)
302 mm(11.89 in)W × 170 mm(6.69 in)H × 52 mm(2.05 in)D, 1.7 kg (59.98 oz) (with Digital I/O Unit, without battery)
Accessories 9418-15 AC ADAPTER (1), Terminal Cover (1), Screwdriver (1), Wave viewer software (1), Interface Manual FD (1)
8420-51 / 8421-51 / 8422-51 product catalog.pdf (1.4 MB) Back
Concerning Noise Countermeasures Users Guide.pdf (719 KB)