Add part number 3280-20 to your Quote. 3280-20 CLAMP ON HiTESTER
Overview
Easy operation ! True RMS
  • 1000 A rms, clamp aperture: 33 mm(1.30 in) dia.
  • Light 100 g(3.5 oz), and Slim 16 mm(0.63 in)
  • Independent-opening double-lever design
  • Slim body design, allows easy clamping even for narrow conductors
  • No metal (iron core) exposure, ensuring enhanced safety
CE CAT III 600 V
(Current range)
CAT II 600 V
(Voltage range)
DCL ULL
Options (Click for picture)
  Add part number 9208 to your Quote. 9208 TEST LEAD - Supplied as standard with the Add part number 3280-20 to your Quote. 3280-20   Add part number 9209 to your Quote. 9209 TEST LEADS HOLDER - for convenient voltage measurement
  Add part number CT-101A to your Quote. CT-101A LINE SPLITTER - Input × 1, or × 10 output, for clamp-on probe   Add part number 9398 to your Quote. 9398 CARRYING CASE - Supplied as standard with the Add part number 3280-20 to your Quote. 3280-20
Basic specifications
AC Current range 42.00 to 1000 A AC, 3 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), Effective value rectifier
AC voltage range 4.200 to 600 V AC, 4 ranges (±2.3 % rdg. ±8 dgt. at 50 or 60Hz), Effective value rectifier
DC voltage range 420.0 mV to 600 V DC, 5 ranges (±1.3 % rdg. ±4 dgt.)
Other functions Resistance: 420.0 to 42.00 M-ohm, 6 ranges, Accuracy: ±2.0 % rdg. ±4 dgt. (at 420 to 420 k-ohm range), Continuity: 420.0 ohm (Buzzer sounds at approx. 50 ohm or less)
Analog output None
Frequency characteristics (at AC current / voltage) AC current: 40 to 1 kHz, AC voltage: 50 to 500 Hz
Display section Digital / LCD, maximum 4199 dgt.
Sampling rate 2.5 times/sec or 1 times/3 sec
Crest factor (RMS) 2.5
Max. circuit voltage 600 V AC rms (insulated wire)
Power supply CR2032 (3 VDC) × 1, Continuous use 50 hours
Core jaw diameter Ø 33 mm(1.30 in)
Dimensions, mass 57 mm(2.24 in)W × 175 mm(6.89 in)H × 16 mm(0.63 in)D, 100 g (22.44 oz)
Accessories 9208 TEST LEAD (1), 9398 CARRYING CASE (1)