connex-electronics.com Hioki
Hioki
Hioki Data Logger Series
2300 Series REMOTE MEASUREMENT SYSTEM
Overview
Build your own customized and low cost remote measuring system by utilizing existing data network
  • Various measurement modules for temperature and humidity, instrumentation, and pulse
  • Power measurement module for multiple circuits
  • Large internal memory to avoid data loss due to communication problems
  • Communication module with built-in real-time clock tracks the data of each measurement module to the second
  • Air Module for constructing SS wireless systems
RS-232C
STANDARD
LAN
STANDARD
Basic specifications
2301-20
HUMIDITY MODULE
Temperature 1ch and humidity 1ch.
Use withoptional sensor 9764
Temperature: -40.0 to 85.0°C
Humidity: 0.0 to 100%RH
2302-20
Pt MODULE
Temperature 2ch (Pt100)
2 types of platinum resistance thermo sensors available
2303-20
TC MODULE
2ch temperature measurement using thermocouples (K, E, J, T). 4 TC types available
2304-21
PULSE MODULE
For 2ch pulse input (voltage,contact), maximum 16M pulses/interval
Input pulse: 4kHz max. (voltage/electroniccontact signal)
25Hz max. (mechanical contact signal)
2305-20
INSTRUMENTATION MODULE
Voltage / current 2ch measurement, for 4-20mA, 1-5V instrumentation signals
2331-20
POWER METER MODULE
For single circuit power measurement.
Single-phase 2-wire to 3-phase 4-wire
Voltage: AC 100/200V (70 to 130VAC/140 to 260VAC)
Current: AC 5A (with 9765 or 9695-02 CLAMP ON SENSOR), AC 50A (with 9695-02) ,AC 100A (with 9695-03 or 9661-01),AC 500A (with 9661-01)
2332-20
POWER METER MODULE
For multiple circuit power measurement: from 6 circuits of single-phase 2-wire to 3 circuits of 3-phase 3-wire installations
Voltage: AC200V (100V accepted at 200V range) (70 to 260VAC)
Current: AC 5A (with 9765 or 9695-02 CLAMP ON SENSOR), AC 50A (with 9695-02), AC 100A (with 9695-03 or 9661-01), AC 500A (with 9661-01)
*3-phase 4-wire circuit cannot be measured
2341-20
INPUT MODULE
For recording the status of contact/voltage signals
8ch input, easily capture on/off status with LED
2342-20
OUTPUT MODULE
Outputs control signal according to commands from above or based on measurement module data; 8ch output (open corrector)
2343-20
RS LINK MODULE
For communicating with RS-232C interface equipped instruments
Interface: RS-232C, Transfer speed: 57.6kbps(max.)
Please inquire regarding compatible instruments.
(Existing compatible HIOKI instruments include Models 3331 and 3332.)
2351-20
AIR MODULE
2.4GHz band SS wireless technology(RS-232Cequipped)
Transfer speed: 51.9kbps(fixed), RS-232C: 57.6kbps(max.)
*Note: Requires modification according to regional or national standards. Contact HIOKI for more information.
2352-20
WIRE MODULE
For small-scale measurement systems or built-in use
Interface: RS-232C, Transfer speed: 57.6kbps (max.)
2353-20
LAN MODULE
For data logging via LAN
Interface: 10BASE-T
2361-20
AC POWER MODULE
Power supply for the communication modules and measurement modules (max. 10 modules)
Input: AC 100 to 240V, Output: DC5V/2.4A
2362-20
DC POWER MODULE
Power supply for the communication modules and measurement modules (max 10 modules)
Input: DC 19 to 36V, Output: DC5V / 2.4A
2391 Series
MODULE BASE
For connecting modules (3 slots reserved for power supply and communication module)
2391-01: For relay and master station
2391-02: 5 measurement module slots
2391-03: 10 measurement module slots
*Model 2331-20 uses 2 slots
2392 Series
MODULE BASE
For connecting modules (also connects with additional module bases for increased measurement capabilities)
2392-01 :1 slot; includes power and internal bus connection terminal
2392-02*:2 slot; connect with 2391-21 for additional measurement modules
* POWER MODULE not compatible; must use with Model 2392-21 to access POWER MODULE
2300 Series REMOTE MEASUREMENT SYSTEM product catalog.pdf (1,468 KB) Back