| Hioki Options
and Peripherals |
 |
| 2103 METER
RELAY |
| OVERVIEW |
| Advancing power saving and automation |
- Electronic design assures high accuracy and
reliability
- Ultra sensitive 1 µA, 10 mV DC movement
- Both power circuitry and relay built-in
- Includes a display lamp to illuminate movement at a
glance
- Relay action delays circuit closure upon power
on
|
|
 |
| Special Specification
Options |
| ±1.5 % class |
for the model 2103 |
| Extended scale |
double or triple extended scale |
| Segmented scale |
magnified scale for up to 40 % of the
maximum scale value |
| Double deflection meter |
for example, zero-centered scale |
| Relay response time |
time constant 0.05 second fixed (DC) and
variable types also available |
| Setting accuracy |
Version with ±1.0 % type |
| Delay time |
Version with variable delay time after
power on. 0.1 to 10 seconds: (for instruments input DC), 2 to 12 seconds: (for
instruments input AC) |
| Output signal |
Version with 1 V DC/f.s. output
terminal Note: not isolated from input circuit ground) |
| Power supply |
Version with 110 / 120 / 220 / 230 / 240V
AC ±10 % |
|
| Basic
specifications |
| Meter class |
±2.5 % class |
| Deflecting range |
Passing type, full scale |
| Setting pointer |
Lance shape, upper limit and lower limit
pointer |
| Setting accuracy |
±1.5 % of scale length |
| Minimum H/L interval |
Within 3 % of scale length |
| Relay power delay circuit |
Approx. 2 second |
| Relay output response |
Approx. 0.5 second |
| Output contact capacity |
5 A (under condition of 250 V AC, 30 V DC,
resistance load) |
| Power supply |
100 or 200 V AC ±10 % (to be
specified at the time of ordering) |
| Dimensions, mass |
84 mm(3.31 in)W(panel size) × 72
mm(2.83 in)H (panel size) × 117.6 mm(4.63 in)H (rear section)
see below |
| Other specifications |
Standard
Scale Graduations Standard Full-Scale
Values at DC Standard Full-Scale Values
at AC Contact operation |
|
| Dimensions -- 2103 / 2104 METER RELAY |
 |
|
| Standard Scale Graduations |
Contact Operation |
 |
 |
|
Std. Full Scale Values: DC Ammeter |
Std. Full
Scale Values: DC Voltmeter |
| Std. Full
scale value |
Meter
sesitivity spec |
Std. Full
scale value |
Meter sesitivity
spec |
| 1 µA |
50 mV |
12 mV |
100 kΩ/V |
| 10 µA |
15 mV |
100 kΩ/V |
| 20 µA |
30 mV |
100 kΩ/V |
| 50 µA |
50 mV *2 |
100 kΩ/V |
| 100 µA |
100 mV |
100 kΩ/V |
| 200 µA |
150 mV |
100 kΩ/V |
| 500 µA |
300 mV |
100 kΩ/V |
| 1 mA *1 |
500 mV |
10 kΩ/V |
| 2 mA |
1 V |
10 kΩ/V |
| 5 mA |
1.5 V |
10 kΩ/V |
| 10 mA |
3 V |
10 kΩ/V |
| 20 mA |
5 V |
10 kΩ/V |
| 50 mA |
10 V |
10 kΩ/V |
| 100 mA |
15 V |
10 kΩ/V |
| 200 mA |
30 V |
10 kΩ/V |
| 500 mA |
50 V |
10 kΩ/V |
| 1 A |
100 V |
10 kΩ/V |
| 2 A |
150 V |
10 kΩ/V |
| 5 A |
300 V |
10 kΩ/V |
| 10 A |
|
| 20 A |
Full Scale: 4-20 mV |
Full Scale: 1-5 V |
10 kΩ/V |
|
Std. Full Scale Values: Rectifying AC Ammeter |
Std. Full
Scale Values: Rectifying AC Voltmeter |
| Std. Full
scale value |
Meter
sesitivity spec |
Std. Full
scale value |
Meter sesitivity
spec |
| 200 µA |
50 mV |
50 mV |
10 kΩ/V |
| 500 µA |
100 mV |
10 kΩ/V |
| 1 mA *3 |
150 mV |
10 kΩ/V |
| 2 mA |
300 mV |
10 kΩ/V |
| 5 mA |
500 mV |
1 kΩ/V |
| 10 mA |
1 V |
1 kΩ/V |
| 20 mA |
1.5 V |
1 kΩ/V |
| 50 mA |
3 V |
1 kΩ/V |
| 100 mA |
5 V *4 |
1 kΩ/V |
| 200 mA |
10 V |
1 kΩ/V |
| 500 mA |
15 V |
1 kΩ/V |
| 1 A |
30 V |
1 kΩ/V |
| 2 A |
50 V |
1 kΩ/V |
| 3 A |
100 V |
1 kΩ/V |
| 5 A |
150 V |
1 kΩ/V |
| |
300 V |
1 kΩ/V |
| *1 -- When the full scale
value is larger than 300 V, an external multiplier is used with the 1 mA
instument. |
| *2 -- When the full scale
value is larger than 20 A, an external shunt device is used with the 50 mV
instument. |
| *3 -- When the full scale
value is larger than 300 V, an external multiplier is used with the 1 mA
instument. |
| *4 -- When the full scale
value is larger than 5 A, an external CT is used with the 5 A instument. |
|
| |