| Finder 86-Series Plug-In Timers
|
| |
| Multi-function & Multi-voltage Timer Module
|
Features:
- Multifunctions
- Use with 90-Series and 92-Series sockets
- Wide supply voltage range (12-240V)
- LED indicator
- See pdf for complete specifications
|
 |
|
| 86.00 - Multi-function & Multi-voltage Timer Modules
|
| Part Number |
Supply Voltage |
Mounting |
Timing Functions |
86.00.0.240.0000 |
12-240V AC/DC |
90.02
90.03
92.03 Sockets |
AI: ON delay
DI: ON pulse
SW: Symmetrical recycling: ON start
BE: Signal OFF delay
CE: Signal ON & OFF delay
DE: Signal ON pulse
EE: Signal OFF pulse
FE: Signal ON delay + OFF pulse |
|
| Single Function & Multi-voltage Timer
Module |
Features:
- Use with 90, 92, 94, and 95-Series sockets
- Wide supply voltage range (12-240V)
- LED indicator
- See pdf for complete specifications
|
 |
|
| 86-Series - Single Function & Multi-voltage Timer Modules
|
| Part Number |
Supply Voltage |
Mounting |
Timing Functions |
86.10.0.024.0000 |
12-24V AC/DC |
90.02
90.03
92.03
94.02
94.03
94.04
95.03
95.05 Sockets |
AI: ON delay |
86.20.0.024.0000 |
DI: ON pulse |
|
| Wiring Diagram |
Timing Diagram |
Timing Function Description
|
|
 |
(AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed.
|
 |
(DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset.
|
 |
(SW) Symmetrical recycler:
ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off).
|
|
 |
(BE) Signal OFF delay. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset.
|
 |
(CE) Signal ON and OFF delay. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset.
|
 |
(DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset.
|
 |
(EE) Signal OFF pulse. Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset.
|
 |
(FE) Signal ON pulse + OFF pulse.
Power is permenently applied to the timer. Both the opening and closing of the Signal Switch (S) initiates the transfer of the output contacts. In both instances T T the contacts reset after the delay period has elapsed.
|